VariableUsage for outputs are not simulated for EntryLevelSystemCall

Description

When an EntryLevelSystemCall in a UsageScenario defines an output parameter, the move of the result value to the parent stackframe is not simulated and cannot be used in subsequent EntryLevelSystemCalls

Environment

None

Activity

Show:
Stephan Seifermann
February 22, 2021, 10:13 AM

Fix has been merged into master.

Stephan Seifermann
February 9, 2021, 4:37 PM

According to today’s concall, there is no particular reason to not support outputs of entry level system calls. Therefore, we can integrate the fix.

Dominik Werle
November 19, 2020, 1:47 PM

The fix is ready ( ), but I suggest waiting until we are sure that this is the wanted behavior.

Fixed

Assignee

Dominik Werle

Reporter

Dominik Werle